D 2021

Brightness levels in MRI should correspond with echogenicity grade in ultrasound B-MODE images: A pilot study of reproducibility using ROI-based measurement between two blind observers

BLAHUTA, Jiří and Tomáš SOUKUP

Basic information

Original name

Brightness levels in MRI should correspond with echogenicity grade in ultrasound B-MODE images: A pilot study of reproducibility using ROI-based measurement between two blind observers

Authors

BLAHUTA, Jiří and Tomáš SOUKUP

Edition

Volume 2962. Slovensko, Proceedings of the 21st Conference Information Technologies – Applications and Theory (ITAT 2021), p. 182-187, 6 pp. 2021

Publisher

CEUR Workshop Proceedings

Other information

Language

English

Type of outcome

Proceedings paper

Field of Study

20600 2.6 Medical engineering

Country of publisher

Slovakia

Confidentiality degree

is not subject to a state or trade secret

Publication form

electronic version available online

References:

Plný text konferenčního příspěvku

Marked to be transferred to RIV

Yes

RIV identification code

RIV/47813059:19240/21:A0000872

Organization unit

Faculty of Philosophy and Science in Opava

ISSN

EID Scopus

2-s2.0-85116620795

Keywords in English

Image analysis; Image segmentation; Magnetic resonance imaging; Medical Imaging; Ultrasonics

Tags

HRAWARDS, RESTART, SGS112019, ÚI

Tags

International impact, Reviewed
Changed: 16/12/2021 17:31, Mgr. Kamil Matula, Ph.D.

Abstract

In the original language

In 2011, we developed a software tool to analysis of the echogenicity level in ultrasound B-MODE images. This software is based on binary thresholding in a predefined Region of Interest (ROI). The goal of this paper is to observe if the echogenicity grade in B-MODE images corresponds with brightness level in MR images using the echogenicity index. Achieved results obtained by two, non-experienced observers in radiology, shows the software can be used also for MRI images. The reproducibility of the measurement evinces the high level of agreement. We use three ROI areas for which the exact position in MR image is not important at this moment. Totally of 52 images were analyzed. Achieved results show the error between measurements by two non-experienced observers does not exceed 5 %; calculated based on the range of the measurements and computed average difference for each image set. Thus, the echogenicity index can be considered as reproducible marker; a small shift of the ROI does not evince significant change. Average range of the index is computed from 28.17 up to 67.95; minimal index value was < 20 and the highest value was 101.2 due to different brightness level in the examined ROI. The range for the same ROI are almost equal, the difference does not exceed 2 %.
Displayed: 19/11/2026 21:13