D
2021
Brightness levels in MRI should correspond with echogenicity grade in ultrasound B-MODE images: A pilot study of reproducibility using ROI-based measurement between two blind observers
BLAHUTA, Jiří and Tomáš SOUKUP
Basic information
Original name
Brightness levels in MRI should correspond with echogenicity grade in ultrasound B-MODE images: A pilot study of reproducibility using ROI-based measurement between two blind observers
Edition
Volume 2962. Slovensko, Proceedings of the 21st Conference Information Technologies – Applications and Theory (ITAT 2021), p. 182-187, 6 pp. 2021
Publisher
CEUR Workshop Proceedings
Other information
Type of outcome
Proceedings paper
Field of Study
20600 2.6 Medical engineering
Country of publisher
Slovakia
Confidentiality degree
is not subject to a state or trade secret
Publication form
electronic version available online
Marked to be transferred to RIV
Yes
RIV identification code
RIV/47813059:19240/21:A0000872
Organization unit
Faculty of Philosophy and Science in Opava
Keywords in English
Image analysis; Image segmentation; Magnetic resonance imaging; Medical Imaging; Ultrasonics
Tags
International impact, Reviewed
In the original language
In 2011, we developed a software tool to analysis of the echogenicity level in ultrasound B-MODE images. This software is based on binary thresholding in a predefined Region of Interest (ROI). The goal of this paper is to observe if the echogenicity grade in B-MODE images corresponds with brightness level in MR images using the echogenicity index. Achieved results obtained by two, non-experienced observers in radiology, shows the software can be used also for MRI images. The reproducibility of the measurement evinces the high level of agreement. We use three ROI areas for which the exact position in MR image is not important at this moment. Totally of 52 images were analyzed. Achieved results show the error between measurements by two non-experienced observers does not exceed 5 %; calculated based on the range of the measurements and computed average difference for each image set. Thus, the echogenicity index can be considered as reproducible marker; a small shift of the ROI does not evince significant change. Average range of the index is computed from 28.17 up to 67.95; minimal index value was < 20 and the highest value was 101.2 due to different brightness level in the examined ROI. The range for the same ROI are almost equal, the difference does not exceed 2 %.
Displayed: 19/11/2026 21:13