J 2023

Peak systolic velocity ratio for evaluation of internal carotid artery stenosis correlated with plaque morphology: substudy results of the ANTIQUE study

PAKIZER, David, Anna VYBÍRALOVÁ, Tomáš JONSZTA, Martin ROUBEC, Michal KRAL et. al.

Základní údaje

Originální název

Peak systolic velocity ratio for evaluation of internal carotid artery stenosis correlated with plaque morphology: substudy results of the ANTIQUE study

Autoři

PAKIZER, David (203 Česká republika), Anna VYBÍRALOVÁ (203 Česká republika), Tomáš JONSZTA (203 Česká republika), Martin ROUBEC (203 Česká republika), Michal KRAL (203 Česká republika), Vendelin CHOVANEC (203 Česká republika), Roman HERZIG (203 Česká republika), Tomáš HERYÁN (203 Česká republika, domácí) a David ŠKOLOUDÍK (203 Česká republika, garant)

Vydání

FRONTIERS IN NEUROLOGY, 2023, 1664-2295

Další údaje

Jazyk

angličtina

Typ výsledku

Článek v odborném periodiku

Obor

30210 Clinical neurology

Stát vydavatele

Švýcarsko

Utajení

není předmětem státního či obchodního tajemství

Kód RIV

RIV/47813059:19520/23:A0000408

Organizační jednotka

Obchodně podnikatelská fakulta v Karviné

UT WoS

001105742200001

Klíčová slova anglicky

carotid stenosis severity; duplex sonography; peak systolic velocity; end-diastolic velocity; computed tomography angiography; plaque morphology
Změněno: 1. 4. 2024 15:53, Miroslava Snopková

Anotace

V originále

Accurate assessment of carotid stenosis severity is important for proper patient management. The present study aimed to compare the evaluation of carotid stenosis severity using four duplex sonography (DUS) measurements, including peak systolic velocity (PSV), PSV ratio in stenosis and distal to stenosis (PSVICA/ICA ratio), end-diastolic velocity (EDV), and B-mode, with computed tomography angiography (CTA), and to evaluate the impact of plaque morphology on correlation between DUS and CTA. Measurements showed comparable correlations with CTA in evaluating carotid artery stenosis based on their correlation with CTA results. Heavy calcifications and plaque surface irregularity or ulceration negatively influenced the measurement accuracy.