D 2021

Brightness levels in MRI should correspond with echogenicity grade in ultrasound B-MODE images: A pilot study of reproducibility using ROI-based measurement between two blind observers

BLAHUTA, Jiří a Tomáš SOUKUP

Základní údaje

Originální název

Brightness levels in MRI should correspond with echogenicity grade in ultrasound B-MODE images: A pilot study of reproducibility using ROI-based measurement between two blind observers

Autoři

BLAHUTA, Jiří a Tomáš SOUKUP

Vydání

Volume 2962. Slovensko, Proceedings of the 21st Conference Information Technologies – Applications and Theory (ITAT 2021), od s. 182-187, 6 s. 2021

Nakladatel

CEUR Workshop Proceedings

Další údaje

Jazyk

angličtina

Typ výsledku

Stať ve sborníku

Obor

20600 2.6 Medical engineering

Stát vydavatele

Slovensko

Utajení

není předmětem státního či obchodního tajemství

Forma vydání

elektronická verze "online"

Označené pro přenos do RIV

Ano

Kód RIV

RIV/47813059:19240/21:A0000872

Organizační jednotka

Filozoficko-přírodovědecká fakulta v Opavě

ISSN

EID Scopus

Klíčová slova anglicky

Image analysis; Image segmentation; Magnetic resonance imaging; Medical Imaging; Ultrasonics

Příznaky

Mezinárodní význam, Recenzováno
Změněno: 16. 12. 2021 17:31, Mgr. Kamil Matula, Ph.D.

Anotace

V originále

In 2011, we developed a software tool to analysis of the echogenicity level in ultrasound B-MODE images. This software is based on binary thresholding in a predefined Region of Interest (ROI). The goal of this paper is to observe if the echogenicity grade in B-MODE images corresponds with brightness level in MR images using the echogenicity index. Achieved results obtained by two, non-experienced observers in radiology, shows the software can be used also for MRI images. The reproducibility of the measurement evinces the high level of agreement. We use three ROI areas for which the exact position in MR image is not important at this moment. Totally of 52 images were analyzed. Achieved results show the error between measurements by two non-experienced observers does not exceed 5 %; calculated based on the range of the measurements and computed average difference for each image set. Thus, the echogenicity index can be considered as reproducible marker; a small shift of the ROI does not evince significant change. Average range of the index is computed from 28.17 up to 67.95; minimal index value was < 20 and the highest value was 101.2 due to different brightness level in the examined ROI. The range for the same ROI are almost equal, the difference does not exceed 2 %.

Přiložené soubory

Blahuta-Soukup_Brightness-Levels-in-MRI.pdf
Požádat o autorskou verzi souboru